This tender outlines a 24-month framework agreement with a single economic operator for the procurement of reagents and consumables for flow cytometry, alongside the lease of a flow cytometer, for the Clinical Hospital Centre Osijek. The required flow cytometer must meet stringent technical specifications, including a minimal Windows 10 operating system, a 24-inch monitor, a color printer, and integrated clinical and experimental software, all with "In Vitro Diagnostic Regulation" (IVDR) certification and compatible reagents. Key performance criteria include a carryover of ≤0.1%, minimal particle size detection of <0.3 μm, residual volume of ≤50 μl, and propellant liquid consumption of <15 mL/min, alongside automatic adjustments, compensation, and compatibility with the Client's existing software and EuroFlow approved kits. Bidders must demonstrate prior goods deliveries within the last five years and the current year, valuing at least the estimated procurement cost, to meet financial standing requirements. Ordered goods must be delivered to specified hospital locations within 30 days of each individual written order.
TENDER BRIEF
The contract timeline is as follows:
The total duration of the framework agreement is 24 months (2 years). The agreement commences from the date of mutual signature by both contracting parties. No specific end date or key milestones/phases are explicitly stated beyond the duration and start condition.
Sources
- 1Opći podaci o postupku nabave.html — “440.000,00 EUR CPV oznaka i naziv: 33696500 Laboratorijski reagensi Dodatni CPV oznaka i naziv: 38434510 Citometri 3.1.1. Količina predmeta nabave Naručitelj je odredio predviđene (okvirne) količine u troškovniku. Stvarn…”
- 2Upute za ponuditelje.html — “od ponuditelja u svrhu objašnjenja i nadopune, dostavu ovjerenog prijevoda od strane ovlaštenog sudskog tumača za jezik s kojeg je prijevod izvršen. 3.6. Rok valjanosti ponude Rok valjanosti ponude je 120 dana od dana is…”
- Operating system: minimal Windows 10 or equivalent
- Monitor: minimum 24 inches diagonal
- Printer: color printer
- Clinical software
- Experimental software
- Platform certification: "In Vitro Diagnostic Regulation" (IVDR)
- Availability of IVDR marked reagents compatible with the offered platform
- Carryover ≤0.1%
- Minimal particle size on front and side scatter <0.3 μm
- Minimal residual volume: 50 μl or less in 12x75mm tubes
- Propellant liquid consumption: <15 mL/min during normal operation
- Automatic adjustment and monitoring of device settings using fluorescent beads
- Automatic compensation during or after acquisition
- Data management for signal area and height parameters for all channels and time
- Software programs for data collection and analysis, both clinical and experimental
- Direct sample injection into the flow cell
- Manual sampling capability
- No limitation on the number of collected events in the FSC file
- Automatic check and correction of laser alignment + daily QC
- EuroFlow approved Multiple Myeloma MRD kit
- Compatibility with the Client's existing software
- Manual sampling from 15 mL and 50 mL tubes
- Bid language: Croatian language and Latin script (with exceptions for foreign terms and internationally recognized expressions, and a requirement for translation of other accompanying documents upon request)
Sources
- 1Tehnička specifikacija uređaja.docx — “Side scater). | | 3. | Injiciranje uzorka izravno u protočnicu. | | 4. | Mogućnost ručnog uzorkovanja | | 5. | "Carryover" ≤0.1%. | | 6. | Minimalna veličina čestica na prednjem i bočnom rasprešenju <0.3 μm. | | 7. | Min…”
- 2Predlošci izjava.docx — “broj prikupljenih događaja u FSC datoteci IMA=0 | Sustav omogućuje prikupljanje broja događaja bez ograničenja. Ova stavka osigurava prikupljanje izuzetno velikog broja stanica u kratkom roku iz jednog spremnika što je p…”
- 3Kriteriji za odabir ponude.docx — “bez ograničenja. Ova stavka osigurava prikupljanje izuzetno velikog broja stanica u kratkom roku iz jednog spremnika što je potrebno i preporučeno kod analize minimalne ostatne bolesti. | 0 3. a) | Automatska provjera i…”
Login to view all answers and insights
Unlock tender brief for freeTENDER DOCUMENTS
DIRECTORY • 8 FILES
- Troškovnik.xlsx28 KBXLSX
- Prijedlog okvirnog sporazuma.docx28 KBDOCX
- Opći podaci o postupku nabave.html41 KBHTML
and 1 other document
Login to view and download all tender documents
Unlock documents for freeASK AI ABOUT THIS TENDER
Can a foreign company apply?
Yes, foreign companies can apply as long as they meet all the requirements set out in the procurement documents.
Login to ask more questions.
Unlock AI tender chat for freeUnlock your tender workflow
Run your first search, evaluate the results, save a daily monitor and start building a pipeline of tenders worth pursuing.