Published

    Serverinių monitoringo sistemos plėtra

    Notice number: 00550004-2026

    🇱🇹 LithuaniaLietuvos oro uostai (PV)Goods

    KEY INFORMATION

    Submission deadline
    Sep 11, 2026
    Location
    🇱🇹 Lithuania
    Contracting authority
    Lietuvos oro uostai (PV)
    Accepted Languages
    Lithuanian
    Tender type
    Goods
    Contract Value
    Published date
    Aug 7, 2026

    TENDER DESCRIPTION

    This tender seeks to procure the development and expansion of an existing server monitoring system, encompassing the supply, installation, configuration, testing, and commissioning of various equipment, including server room door readers, rack locks, door position sensors, humidity and temperature sensors, door magnets, video surveillance cameras, and Kentix system communication bus, across the buyer's branches in Vilnius, Kaunas, and Palanga. The solution must integrate seamlessly with the existing Kentix monitoring system and KentixONE platform, adhering to specific technical standards for components such as PoE, Ethernet 10/100 Mbps, RFID, BLE, and detailed specifications for cameras (e.g., 4MP dome type, -30°C to +50°C operating temp) and 42U commutation cabinets. The successful contractor must possess specialists with prior experience in server room system deployment (project value ≥ 30,000 EUR ex. VAT within the last 3 years) and certified training on the Kentix monitoring system. The total contract duration for goods supply and service provision is 36 months from the effective date, with individual orders to be fulfilled within one month.

    TENDER BRIEF

    The contract starts from the effective date of the contract. The total duration for both goods supply and service provision is 36 months from the contract effective date. Individual orders for services and goods have a fulfillment term of 1 month from the order submission date. The contract remains valid until the full fulfillment of all contractual obligations.

    Sources

    • 1SPS priedas Nr. 7. SSS.pdf — “pagal šią Sutartį. Netaikoma ☐ ☑ -Dokumentai, nurodyti Techninėje specifikacijoje. Ant pristatytų Prekių pakuotės turi būti nurodomi Pirkėjo kontaktinio asmens, atsakingo už Sutarties vykdymą, duomenys (Sutarties SS 1 Pr…
    • 2SPS priedas Nr. 7. BSS.pdf — “pažeidimas laikomas esminiu Sutarties pažeidimu, dėl kurio Pirkėjas įgyja teisę vienašališkai nutraukti Sutartį su Tiekėju. 21.4. Šalims, suderinus naujo specialisto kandidatūrą, specialisto keitimas įforminamas raštu su…

    • Kentix monitoring system
    • KentixONE platform
    • PoE (Power over Ethernet) (IEEE 802.3af)
    • Ethernet 10/100 Mbps
    • RFID (Radio-Frequency Identification)
    • MIFARE Classic / DESFire
    • BLE (Bluetooth Low Energy) (2.4 GHz radio connection)
    • AccessManager for KentixONE platform
    • SiteManager for KentixONE platform
    • SmartPDU
    • RS485 magistralė for Kentix system communication
    • CMOS image sensor for video cameras
    • IR-Cut filter (ICR) for day/night camera mode
    • 19" standard for server racks, according to IEC 60297 and other applicable standards like EN 60950 or equivalent
    • Video cameras must be dome type with a CMOS image sensor in the range of 1/3.2" to 1/2.3".
    • Minimum illumination for cameras: 0.01 Lux in color mode and 0 Lux with IR on.
    • IR illumination for cameras must be at least 10 m.
    • Camera resolution must be at least 4 MP.
    • Camera operating temperature must be not less than -30°C to +50°C with a tolerance of no more than 10°C.
    • Camera power must be DC 12V ±10% or PoE (802.3af).
    • Camera frame rate must be 25/30 fps at 1080p.
    • Commutation cabinet width and depth deviation must be no more than ±50 mm and must not impair functionality, fastening, or compatibility with the Kentix lock system.
    • Commutation cabinets must be metal construction with front and rear perforated doors and locks compatible with the Kentix electronic lock system.
    • Commutation cabinet height must be 42U.
    • Commutation cabinet width must be 800 mm (±50 mm).
    • Commutation cabinet depth must be 800 mm (±50 mm) or 1000 mm (±50 mm).
    • Commutation cabinet material must be powder-coated steel.
    • Commutation cabinet doors must be perforated, with rear metal doors.
    • Commutation cabinet height adjustment must be with wheels or adjustable feet.
    • Commutation cabinet mounting rails must include 4 vertical 19" rails, depth adjustable.
    • Commutation cabinet ventilation must be natural with the possibility to install fans at the top.
    • Commutation cabinet cable entries must be at the top and bottom, with covers.
    • Commutation cabinet lockable parts must include front and rear doors and side walls.
    • Commutation cabinet color must be Black RAL9005 or equivalent.
    • Commutation cabinet lock control must be via Ethernet (PoE) or radio (BLE) through AccessManager or SmartPDU with the KentixONE platform.
    • Commutation cabinet lock power must be PoE (IEEE 802.3af) or 1x lithium AA battery 3.6 V (ER14505) with up to 8 years or approximately 100,000 cycles lifespan for BLE locks.
    • Commutation cabinet lock authentication must be RFID (MIFARE Classic / DESFire) plus PIN.
    • Commutation cabinet lock connection must be RJ45 (CAT5e/6a/7) up to 100 m for Ethernet, or Radio (BLE 2.4 GHz) for radio locks.
    • Commutation cabinet lock programming and configuration must be via KentixONE Web UI through AccessManager.
    • Commutation cabinet lock mounting type must be bolt-on to the cabinet handle or door.
    • Commutation cabinet lock protection class must be IP30 for indoor use.
    • Commutation cabinet lock color must be Black RAL9005 or equivalent.
    • Door position sensor control must be via radio (BLE) through AccessManager with the KentixONE platform.
    • Door position sensor power must be AA type lithium battery.
    • Door position sensor mounting must use magnetic contact adapting to shape, bolt-on, or adhesive tape to a door/window frame.
    • Door position sensor must be universally compatible and work with the KentixONE system via BLE network.
    • Door position sensor indication must be LED red/green.
    • Door position sensor connection must be Radio (BLE 2.4 GHz).
    • Door position sensor programming and configuration must be via KentixONE Web UI through AccessManager or SiteManager.
    • Door position sensor protection class must be IP30 for indoor use.
    • Door position sensor color must be Black RAL9005 or equivalent.
    • Server room door readers must be internal and flush wall-mounted.
    • Server room door readers must use RFID authentication.
    • Server room door readers connection and power must be PoE and Ethernet 10/100 Mbps.
    • Server room door readers protection class must be not lower than IP20 for indoor use.
    • Humidity and temperature sensor interface and connection must be PoE (Ethernet 10/100 Mbps) plus radio (BLE), with integrated LAN.
    • Humidity and temperature sensor autonomous stand-alone mode with KentixONE must be possible.
    • Humidity and temperature sensor main sensors must include temperature, humidity, dew point, CO, VOC, air pressure, movement, and vibration.
    • Humidity and temperature sensor accuracy must be ±1% for temperature and ±5% for humidity.
    • Humidity and temperature sensor mounting must be ceiling-mounted or inside a cabinet with a 19" bracket.
    • Humidity and temperature sensor programming must be via KentixONE locally or centrally.
    • Humidity and temperature sensor special functions must include thermal analysis and early fire detection, CO, VOC, and air quality.
    • Economic efficiency assessment methodology for proposals must include criteria for price, specialist's experience, and specialist's training on the Kentix system.
    • Overall system expansion work requires detailed technical documentation including IP address scheme, login credentials, commutation tables, logical and structural diagrams, and a list of installed devices with models and serial numbers.
    • Installation, connection, and integration services into the existing Kentix system are required.
    • The specialist for contract execution must have participated in at least one finished project within the last 3 years involving installation, deployment, and/or configuration of server room or equivalent system equipment/components, with a project value of at least 30,000 EUR excluding VAT.
    • The specialist for contract execution must be trained in deploying and/or configuring components for the Kentix monitoring system.
    • The proposal form must be submitted in Lithuanian.
    • Other documents may be in Lithuanian and/or English, with translations to Lithuanian or English required if documents are in another language.

    Sources

    • 1SPS priedas Nr. 2. Pasiulymo forma.docx — “| | ... | | | Pastaba: kartu su Pasiūlymu Tiekėjas turi pateikti įrodymus, kad vykdant Sutartį bus prieinami lentelėje nurodytų subtiekėjų pajėgumai (užpildytas ir pasirašytas SPS priedas Nr. 13). INFORMACIJA APIE SIŪLOM…
    • 2SPS priedas Nr. 1.1. TS reikalavimų atitiktis.xlsx — “sistema. ",, "Įrašyti Siūlomos prekės gamintojo pavadinimas, modelis ir (ar) prekės kodas",,, "Įrašyti Pateikiama tiksli (-ios) nuoroda (-os) į prekės specifikacijas internetiniame tinklalapyje, kurioje (-iose) galima ra…
    • 3SPS Priedas Nr. 1. Techninė specifikacija.pdf — “būti montuojamos Pirkėjo filialuose: Vilniuje, Kaune, Palangoje. 2.8. Montavimo vietos bus derinamos su Pirkėju Prekių užsakymo metu. 2.9. Lentelė Nr. 1 – perkamų Prekių/Paslaugų sąrašas ir preliminarūs jų kiekiai (detal…
    • 4SPS priedas Nr. 2.1. Pasiūlymo įkainiai.xlsx — “,,,,Pasiūlymo priedas , ,,,,, Serverinių monitoringo sistemos plėtra,,,,, ,,,,, ,,,,Pildo tiekėjas, Eil. Nr.,Prekės / paslaugos pavadinimas,Preliminarus kiekis1,Mato vnt. ,"1 mato vieneto įkainis, EUR be PVM","Kaina Eur,…

    Login to view all answers and insights

    Unlock tender brief for free

    TENDER DOCUMENTS

    DIRECTORY • 23 FILES

    • 9077490_Contract notice - sectoral directive, standard regime_0.pdf
    • 2_c4t_9077490_1.xml
    • SPS Priedas Nr. 15. Sandorio šalies ir(ar) subtiekėjo duomenys.docx

    and 16 other documents

    Login to view and download all tender documents

    Unlock documents for free

    ASK AI ABOUT THIS TENDER

    You

    Can a foreign company apply?

    Riko

    Yes, foreign companies can apply as long as they meet all the requirements set out in the procurement documents.

    Login to ask more questions.

    Unlock AI tender chat for free

    Unlock your tender workflow

    Run your first search, evaluate the results, save a daily monitor and start building a pipeline of tenders worth pursuing.

    First monitor on Day 1All features included in trialNo credit card required

    You may also be interested in

    Similar tenders